Home ProductsNucleic Acid Extraction Kit

Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit

I'm Online Chat Now

Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit

Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit
Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit

Large Image :  Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit

Product Details:
Place of Origin: CHINA
Brand Name: Renji Medical
Certification: CE, SGS, MSDS, YBTC, MA
Model Number: RJ-B
Payment & Shipping Terms:
Minimum Order Quantity: 100 boxes
Price: Negotiable
Packaging Details: 48 tests/ box
Delivery Time: 5-8 working days
Payment Terms: T/T. 50% deposit before production, balance be paid before shipping.
Supply Ability: 500K pieces per day

Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit

Description
Product Name: Viral RNA & DNA Extraction Kit Method: Spin Column Method
Sample Volume: Up To 200uL Of Sample Sample Type: Serum, Plasma, Nasopharyngeal Swab, Cell Preservation Solution, Tissue Fluid, Urine And Secretions
Applied In: PCR, RT-PCR, QPCR, QRT-PCR, Etc. Operation Process: Simple, Quick, And Non-toxic
Packing: 50 Tests/Kit Extraction Time: 15 Minutes For 32 Samples
Capacity: 500K Pieces Per Day Store Temperature: 5 - 25 ℃
Vadidation: 12 Months
High Light:

CSF Nucleic Acid Extraction Kit

,

Spin Column Viral Rna Isolation Kit

,

CSF Viral Rna Isolation Kit

Viral DNA/ RNA Kit is a product designed to extract high-purity

viral DNA/ RNA from c serum, plasma, CSF, saliva, swab and cell

free body fluid samples using the automated nucleic acid

extraction instrument

 

PRODUCT NAME
 
Viral RNA&DNA Extraction Kit
 
METHOD
 
Spin Column Method
 
Spin Column Viral DNA/RNA Extraction Kit utilizes a unique lysis buffer to lyse
virus and release DNA / RNA. The released DNA / RNA is effectively purified after
specifically binding to a silica-based spin column. It is suitable for isolating viral
DNA/RNA from up to 200 μl of plasma, serum, whole blood, tissue homogenate,
cell-free body fluid, nasopharyngeal or oropharyngeal aspirate/wash, bronchoalveolar
lavage fluid (BALF), tracheal aspirate, sputum, nasopharyngeal or oropharyngeal swab
and animal cell culture supernatant. The isolated DNA/RNA with high purity can be
applied in PCR, RT-PCR, qPCR, qRT-PCR, etc.
 
Using classic silica membrane adsorption technology and unique buffer system,
Virus DNA/RNA extraction Kits (spin column) can extract DNA/RNA from blood,
tissue, organs, environmental sample, saliva and nasal sample, and maximum
remove impurities protein and other organic compound impurities. The extracted
virus DNA/RNA can be directly used for downstream applications such as PCR,
RT-PCR, qPCR and qRT-PCR experiment.
 
APPLICATIONS
  • Extraction of viral RNA and DNA and microbial DNA from clinical samples
  • Clinical testing applications
  • Suitable for DNA/RNA extraction from blood, animal tissue, environmental
         sample, saliva, nasal liquid and swab sample.

 

FEATURES

 

Viral RNA&DNA Extraction Kit (Spin column) The kit utilizes a silica-based membrane

technology in the form of a convenient spin column. Viral nucleic acids from lysed

samples bind to the column membrane while impurities are effectively removed

during subsequent washing and centrifugation steps. Ready-to-use nucleic acids

are eluted from the column.

 

The operation process is simple, quick, and non-toxic
High purity DNA/RNA, stable quality
 
Benefits
  • Comprehensive sample type
    Highly-pure viral RNA extraction from various clinical samples such as serum,

         blood samples, CSF (Cerebrospinal Fluid), urine, swab, etc.

  • Poly(A) powder
    Maximized RNA degradation protection and binding efficiency
  • High binding capacity
    Utilization of Silica Magnetic Particles developed and produced by proprietary

          technology

  • Convenience
    Ethanol already added to the Wash Buffer

Application

  • cDNA synthesis
  • RT-PCR
  • Quantative real-time RT-PCR
  • poly A+ RNA selection
  • Northern blot analysis
  • Pathogen detection
Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit 0
Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit 1

 

PACKAGE SPECIFICATION
 
50 tests/kit
 
INTENDED USE
 
This kit is used to extract DNA/RNA from plasma, serum, animal tissues, body fluids
and other samples. The sample is processed by the lysis solution to release DNA/RNA.
At the same time, a special polymer membrane material is used to selectively adsorb
viral DNA/RNA, and then after washing and elution operations, high-purity viral
DNA/RNA can be obtained. The nucleic acid extracted by this kit can be used for
Real-time PCR, Nothern Blot, Blotting Hybridization, cDNA Library Construction.
 
The kit can be used for both research purposes and in vitro diagnosis (IVD) and
is validated for COVID-19 diagnosis.
 
COMPONENTS OF THE KIT
No. Reagent Name Spec. & Qty
1 Lysis Solution 15mlx 1 Bottle
2 Wash Buffer I 8ml×1 Bottle (add 24ml absolute ethanol before the first use)
3 Wash BufferⅡ 8ml×1 Bottle (add 24ml absolute ethanol before the first use)
4 Elution Solution 3mlx 1 Bottle
5 Adsorption Column 50×1 Pack
6 Collection Tube
50×1 Pack

Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit 2

 

STORAGEAND STABILITY
The kit should be stored at room temperature 5-25℃. The kit is valid for 12 months.
 

【Self Provide Materials】

Sterilized 1.5ml centrifuge tube, Sterilized tips of various specifications, centrifuge,

absolute ethanol, vortex mixer, etc.

 
SPECIMEN REQUIREMENTS
1. The virus in liquid samples such as whole blood, plasma, serum, ascites, oral fluid
can be directly extracted.
2. The virus in animal and plant tissues needs to add an appropriate amount of saline
or PBS to the sample, grind it thoroughly, centrifuge at 12000rpm for 5-10 minutes,
and take the Supernatant for use
 
SPECIMEN EXTRATION OPERATION
Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit 3
Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit 4
1. Add 300ul of the processed sample to a 1.5ml clean centrifuge tube (if less than
300ul, please make up to 300ul with PBS or saline), and then add 300ul of Lysis
Solution. Cap the tube and vortex for 30 seconds.
2. Incubate it at room temperature for 10 minutes.
3. Add 200ul of absolute ethanol to the centrifuge tube, cap the tube, and vortex for
15 seconds. Centrifuge briefly to collect the solution on the tube wall and tube cap.
4. Put the Adsorption Column into the Collection Tube, transfer the above mixed
solution to the Adsorption Column, centrifuge at 8000rpm for 1 minute, and discard
the solution in the Collection Tube.
5. Add 600ul of Washing Buffer I to the Adsorption Column (confirm that absolute
ethanol was added to Washing Solution I before use), centrifuge at 8000rpm for
1 minute, and discard the solution in the Collection Tube.
6. Add 600ul of Washing BufferⅡto the Adsorption Column (confirm that absolute
ethanol was added to Washing SolutionⅡbefore use), centrifuge at 8000rpm for l
minute, and discard the solution in the Collection Tube.
7. Put the Adsorption Column back into the collection tube and centrifuge at 8000rpm
for 2 minutes, discard the solution in the Collection Tube.
8. Transfer the Adsorption Column to a new 1.5ml centrifuge tube, add 50pl of
Elution Solution to the Adsorption Column and incubate at room temperature
for 2 minutes.
9. Centrifuge at 8000rpm for 1 minute and discard the Adsorption Column.
The solution in the 1.5ml centrifuge tube contains DNA/RNA. The extracted DNA/RNA
can be directly used in Real-time PCR, Nothern Blot, Blotting Hybridization, cDNA
Library Construction and other experiments. If you do not use it immediately,
please store it at-20℃.
 
PRODUCT PERFORMANCE INDEX
1. The purity:The ratio of absorbance OD260/OD280 is between 1.8-2.2.
2. The precision:The coefficient of variation (CV) of the RNA/DNA content is≤5%.
 
【SAMPLE REQUIREMENTS
• Store at 4°C for no more than 72 hours; at -70°C for long term storage
• Avoid repeated freezing and thawing
• Swab samples should only be collected with synthetic tip swabs with aluminum or
   plastic shafts.
 
 
PRECAUTIONS
1. Please read this kit operating instructions carefully before use, and operate carefully
as required.
2. The virus has a strong infection ability, and various defense measures must be
prepared before operation.
3. Wear clean gloves and masks during operation.
4. Use RNase/DNase-free tips and 1.5ml centrifuge tubes.
5. All centrifugation steps are performed at room temperature (5-25℃).
6. Frozen samples need to be thawed to room temperature.
7. Need to bring your own absolute ethanol and 75% ethanol,
8. Do not use products beyond the expiration date; do not mix reagents of different
lot numbers.

 

INDEX OF SYMBOL

Spin Column Nucleic Acid Extraction Kit , CSF Viral Rna Isolation Kit 5

 

EXPORTER

Magnus International Limited

 

F12, New City International Mansion A, 234 Huapao Ave.

Liuyang, Hunan Province 410300 China

 

Contact: Goodwellmedical@gmail.com

 

AUTHORIZED REPRESENTATIVE

 

Lotus NL B.V.

Koningin Julianaplein 10, 1e Verd, 2595AA, The Hague, Netherlands.

 

FACTORY VIEW

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 3

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 4

 

FACTORY WORKSHOP

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 5

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 6

 

PRODUCT AND STANDARDS

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 7

 

【CERTIFICATIONS】

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 9

 

Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 10

 

【FAQ

 
1. Q: How about your healthcare and medical product quality?
 
A: Quality is our top priority. We have a professional quality control team to ensure the
quality with a high standard and regulated with the pro certifications. The QC team is
responsible for quality checking in each process and inspects every batch of our production
and ships them only after QC approval.
 
2. Q: What is your order MOQ?
 
A: Please contact customer service, and the price is negotiable for a large quantity.
 
3. Q: How about your product packing for shipment or mailing?
 
A: We prepared a well neutral package for our products. We could also make OEM packages,
OEM/ODM Custom Package/Multi-packing package/Cartons with well protective wrapping.
 
4. Q: What level of your product price?
 
A: We are the factory and direct manufacturer and offer competitive prices. We also offer
volume pricing with more benefits depending on your order quantity level. Please let us know
your ordering volume while you make the inquiry to us to help you obtain better benefits.
 
5. Q: What're the price terms?
 
A: The price is based on the FOB of Hunan, China with an exchange rate of RMB6.40 for
USD$1.00. If the exchange rate floating sharply lower than 6.3 or higher than 6.5, we should
adjust the price with the real-time exchange rate.
 
6. Q: What're the payment terms?
 
A: We accept T/T wire transferring, PayPal, Western Union, etc. 50% down payment after
signing the contract and rest 50% before shipping confirmation.
 
7. Q: How could I get some samples?
 
A: We are able to deduct your samples expense once your orders are confirmed with us.
The shipping fee will be calculated with the sample volume that you demand.
 
8. Q: Could you accept OEM orders?
 
A: Yes, we could. We have professional designers who can design the logo or artwork and offer
best solution & styles for your OEM product choices.
 
9. Q: How long will the shipping or express take?
 
A: (1) For the international express such as DHL, UPS, FedEx, TNT, or EMS, etc., it usually
takes 5-7 working days to your location or destination.
(2) If shipping with containers, they will take about 30-60 days to process depending on
the various ports or door locations.
(3) We will arrange the delivery or shipping of your products within 1-3 days after full
payment has been confirmed. We may not ship your products out until your payments arrive
to our bank account successfully.
 
10. Q: How do you deliver the goods to us?
 
A: If the order of small volume package, we could deliver by courier such as DHL, UPS, FedEx,
TNT, EMS. For the large volume order, we could ship with bulk cargo containers by sea.
We will provide you with cost-saving recommendations for your product shipping.
 
11. Q: What is the warranty time.
 
A: One year for each product.
 
Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 8
 
SHIPPING
 
Sterile Pipette Tips, Filtered, DNAse and RNAse Free, Autoclavable - 200 µl 11
 
We are the trusted healthcare and medical supplies from China.
Be free to contact us at any time!

You are very welcome to email us today at:
Goodwellmedical@gmail.com for the inquiry!

We are excited to build a reliable and long-term business with you
at our best!

Contact Details
MAGNUS INTERNATIONAL LIMITED

Contact Person: Marx Wu

Tel: +8613507415915

Send your inquiry directly to us (0 / 3000)